Display instantaneous flow, cumulative weight, overflow alarm state; Can display the original parameter value, new input parameter value, operation state prompt: can display zero value, tare value, net weight value, A /D conversion digital quantity, speed sensor pulse number;
1. Product details
Accuracy: better than 0.025%;
Dot matrix Chinese fluorescent display;
Rolling, drop-down menu mode;
Display instantaneous flow, cumulative weight, overflow alarm state;
Can display the original parameter value, new input parameter value, operation state prompt: can display zero value, tare value, net weight value, A /D conversion digital quantity, speed sensor pulse number;
32-bit microprocessor with non-volatile memory EPROM. The calibration data entered by the keyboard is stored in a CMOSRAM with a backup battery for ten years.
Alarm and control function: with sound and light alarm function and output control function: touch key input, the input status and prompt can be displayed by dot matrix digital fluorescent screen;
Analog signal input: 0~20mV and 0~30mV;
Two analog current output: one 4~20mA instantaneous flow output, one 4~20mA control current output;
Communication interface: RS-232 /RS-485;
P.I.Dcontrol
Ratio: 5 to 500% ratio band
Integral: 0.01-10min
Differential: 0.01-10min
P.E.I.C(periodic error integration control)
Integration: 0.01-10min
Relay: 1-100S
Control loop: Two separate control loops
Control the amount of feed
Other devices can be controlled